Electrical switchgear equipment

NEW SWITCHGEAR MANUFACTURING / RESOURCES

Switchgear Metering and Monitoring

Switchgear metering is most useful when the specification begins with decisions, not a device catalog. Define whether the project needs service billing, feeder allocation, demand tracking, energy reporting…

U.S.Manufacturing focus
NewCustom project-led builds
NationwideProject support
Made in the USA
Short lead times, confirmed per project
UL 891 subject to project scope
Nationwide delivery planning

Start With the Decisions the Meter Must Support

Switchgear metering is most useful when the specification begins with decisions, not a device catalog. Define whether the project needs service billing, feeder allocation, demand tracking, energy reporting, power-quality visibility, protective relay inputs, or operating status. A main meter may answer questions about total facility consumption, while feeder-level points can help compare tenants, production areas, or major loads. List who will read the data, how often readings are needed, and what action follows an alarm or trend. This scope gives the manufacturer a clear basis for arranging metering points in a new custom lineup and prevents a communications feature from being added without a practical purpose.

Select Measurement Points Around the Power Path

Map measurement locations directly onto the one-line diagram. Candidate points can include the incoming service, each main device, a bus tie, generator or alternate-source connection, transformer secondary, and selected feeders. For every point, identify phase arrangement, conductor relationship, expected current, voltage reference, and whether the measurement is upstream or downstream of a switching device. CT placement, voltage sensing, fusing, and accessible test provisions require coordination with the equipment design and installation method. A clean point list also clarifies whether a tie meter should represent one bus section, both sources, or only the active operating path under the specified sequence.

Match Instruments to the Required Accuracy

Accuracy is a system requirement rather than a generic label on a meter face. Determine the intended use, required measurement quantities, nominal system conditions, burden and ratio considerations, and the acceptable treatment of low-load readings. Revenue-related measurement may involve utility or owner requirements that differ from operational trending. For monitoring, useful quantities may include volts, amperes, real power, reactive power, apparent power, power factor, frequency, energy, and demand interval values. The equipment specification should state which values are required, where current and voltage signals originate, and how scaling will be documented. Final instrument selection remains subject to the project engineer's review and applicable requirements.

Plan Communications as Part of the Electrical Package

A communicating meter is only one part of an information path. Specify the intended protocol, network ownership, addressing method, isolation expectations, connector or terminal arrangement, and the destination system, such as a building management platform, energy dashboard, or supervisory control system. Confirm whether the owner needs read-only values, alarms, remote configuration, time synchronization, or logged data at the device. Ask who supplies network switches, gateways, cables, and software integration. The switchgear package should identify point names, units, scaling, status meanings, and a register or data map when applicable, while avoiding assumptions about a customer's network architecture or cybersecurity policy.

Coordinate Metering With Layout and Maintenance

Metering choices affect the physical lineup as well as the wiring diagram. Reserve panel space, viewing position, instrument compartments, terminal access, and routing paths for power and communication conductors. Consider whether an operator can read local values without entering a restricted area, and whether a qualified technician can isolate instrument circuits for testing without disturbing primary distribution. Separate control and communication wiring where the design requires it, label both ends of conductors, and show removable links or test blocks on drawings. Door swing, enclosure environment, heat, lighting, and cable entry should be reviewed with the room layout and installation clearances rather than treated as afterthoughts.

Define the Metering Submittal and Verification Plan

A useful submittal connects the measurement plan to the finished equipment. Request an annotated one-line diagram, meter schedule, instrument ratios, wiring diagrams, terminal details, communication points, labels, and the proposed data map. Establish how continuity, polarity, ratio information, display configuration, alarm behavior, and communications will be checked during project testing. If a factory witness or field commissioning activity is desired, identify its scope and acceptance records before fabrication. Switchgear Builders manufactures new custom electrical switchgear in the United States using American components and ships nationwide; project drawings and commercial terms should confirm the metering scope, destination, and responsibilities.

GOOD TO KNOW

Questions & answers.

Practical answers to help you plan the next step.

Should every switchgear lineup include feeder meters?

No. Feeder meters should be selected when their operational, allocation, billing, or analytical purpose justifies the added instruments and wiring.

What information should accompany a request for metering?

Provide the one-line diagram, source and feeder list, measurement goals, system conditions, desired quantities, accuracy needs, protocol, destination system, and documentation expectations.

Can switchgear meters communicate with a building management system?

They may, when the selected meter, protocol, gateway, network, and software mapping are compatible and the project team assigns integration responsibilities clearly.

How should a main-tie-main lineup handle metering points?

Define whether the design needs source, bus-section, tie, or load measurements, then document the operating sequence and which values remain meaningful in each state.

LET’S BUILD SOMETHING THAT WORKS

Tell us about your project.

Share the essentials and start a conversation about new switchgear requirements, specifications and schedule.